Quantum dots improve peptide detection in MALDI MS in a size dependent manner

Julian Bailes, Mikhail Soloviev, Loïc Vidal and Dimitri A Ivanov

(2009)

Julian Bailes, Mikhail Soloviev, Loïc Vidal and Dimitri A Ivanov (2009) Quantum dots improve peptide detection in MALDI MS in a size dependent manner. Journal of Nanobiotechnology, 7 (10). pp. . ISSN 1477-3155

Our Full Text Deposits

Full text access: Open

Full Text - 2.62 MB

Links to Copies of this Item Held Elsewhere


Abstract

Laser Desorption Ionization Mass Spectrometry employs matrix which is co-crystallised with the analyte to achieve "soft ionization" that is the formation of ions without fragmentation. A variety of matrix-free and matrix-assisted LDI techniques and matrices have been reported to date. LDI has been achieved using ultra fine metal powders (UFMPs), desorption ionisation on silicon (DIOS), sol-gel assisted laser desorption/ionization (SGALDI), as well as with common MALDI matrices such as 2,5-dihydroxy benzoic acid (DHB), 3,5-dimethoxy-4-hydroxycinnamic acid (SA), α-cyano-4-hydroxycinnamic acid (CHCA) to name a few. A variety of matrix additives have been shown to improve matrix assisted desorption, including silicon nanowires (SiNW), carbon nanotubes (CNT), metal nanoparticles and nanodots. To our knowledge no evidence exists for the application of highly fluorescent CdSe/ZnS quantum dots to enhance MALDI desorption of biological samples. Here we report that although CdSe/ZnS quantum dots on their own can not substitute matrix in MALDI-MS, their presence has a moderately positive effect on MALDI desorption, improves the signal-to-noise ratio, peak quality and increases the number of detected peptides and the overall sequence coverage.

Information about this Version

This is a Published version
This version's date is: 31/12/2009
This item is peer reviewed

Link to this Version

https://repository.royalholloway.ac.uk/items/63f2234e-9bec-cf4f-202d-c2a8b54a93f0/1/

Item TypeJournal Article
TitleQuantum dots improve peptide detection in MALDI MS in a size dependent manner
AuthorsBailes, Julian
Soloviev, Mikhail
Vidal, Loïc
Ivanov, Dimitri
DepartmentsFaculty of Science\Biological Science

Identifiers

doi10.1186/1477-3155-7-10

Deposited by () on 08-Mar-2011 in Royal Holloway Research Online.Last modified on 08-Mar-2011

Notes

© 2009 Bailes et al; licensee BioMed Central Ltd.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

References


Details